RX1270
Numéro d'article: 22086
Prix sur demande

Eye relief with comfort light
The built-in comfort light gently illuminates the wall behind the monitor without interfering with the low ambient lighting typical of reading rooms. This reduces the contrast between the wall and monitor to prevent eye fatigue without creating glare on the screen.
Easily navigate your workspace
It is also equipped with a spotlight which allows you to see printed documents or your keyboard. The position can be easily adjusted in order to achieve the ideal lighting.
Compact and feature-packed
The monitor realizes the ultra-high resolution of 12 megapixels on a 30.9-inch screen. The new design is more compact compared to two conventional 5 megapixel monitors used side by side. This all while including a built-in comfort light and internal power supply that do not impose on the workspace.
Work-and-Flow: Evolve Your Image Reading
As more image modalities become digitalized, radiologists are viewing an increasing amount of information on their screens. EIZO's unique Work-and-Flow technology alleviates the complexity of the imaging workflow with new functions developed with the radiologist in mind. Users can take advantage of Work-and-Flow features with the bundled RadiCS LE software.
Point-and-Focus: Simply select and focus
With the point-and-focus function, relevant image areas can be quickly and easily selected and focused using the mouse or keyboard. To optimize the display for interpretation, the brightness and grayscale tones of specific screen areas can be adjusted as needed.


Hide-and-Seek: Quick Information Referencing
The Hide-and-Seek function enables users to easily hide the PinP (Picture in Picture) window not currently in use and reopen it as needed by moving the mouse cursor to the edge of the screen. This allows for quick and efficient viewing of reports, patient charts, and other information.


Switch-and-Go: Barrier-Free Workstyle
With the Switch-and-Go function, USB switching is done within the monitor. This allows you to use a single keyboard and mouse across two PCs. Users can easily work on either PC by simply moving the mouse cursor across the screens. This enhances work efficiency and creates a cleaner workspace.


Hybrid Gamma PXL: Display both monochrome and color
The Hybrid Gamma PXL function automatically distinguishes between monochrome and color images pixel by pixel, creating a hybrid display where each pixel has optimum grayscale. This gives it greater accuracy and reliability than the conventional area-detection method.
Achieve clarity true to the source data
A medical monitor needs to be capable of high brightness in order to meet performance standards. However, in order to achieve high brightness in an LCD panel, the pixel aperture ratio has to be increased. This causes a typically unavoidable decline in sharpness. With EIZO's unique Sharpness Recovery technology, the decrease in sharpness (MTF) is restored . This allows you to display an image safely on the monitor that is true to the original source data, even at high brightness levels.
MTF measures numerically how faithfully the panel transfers detail from the original image data for viewing. When Sharpness Recovery is turned on, in the case of a 2 pixel line pair (spatial frequency of 1.609 cycles/mm) the MTF increases by approximately 56%.
Reduce reflections for image clarity
Anti-reflection (AR) coating greatly reduces reflections caused by outside light without affecting the light emitting from the monitor. This makes AR preferred over AG (anti-glare) treatments which cause blacks to appear washed out due to diffusion of the backlight. Monitors with AR coating display digital mammography, chest X-ray, and other high-resolution images with more clarity for accurate analysis.

Clear, high density images
With 0.1554 mm pixel pitch, high-density, high-definition image is achieved without appearing grainy.
One-cable connection
With DisplayPort 1.4, a 12 megapixel signal can be supported at 60 frames per second using a single cable between the monitor and the workstation.
Stable display using AI
The color and brightness of an LCD monitor can shift due to changes in ambient temperature and the temperature of the monitor itself. Medical Imaging RadiForce monitors are equipped with a temperature sensor for accurately measuring the temperature inside the monitor, as well as estimating the temperature of the surrounding environment. With this technology, the monitor adjusts in real-time so gradations, color, brightness, and other characteristics continue to display accurately.
Furthermore, EIZO uses AI (artificial intelligence) in the estimation algorithm of the RX1270 so it can distinguish between changing temperature patterns to calculate an even more accurate correction.

Manage effortless quality control
An Integrated Front Sensor (IFS) housed within the front bezel measures brightness and grayscale tones and calibrates to the DICOM Part 14 standard. The hands-free IFS performs quality control tasks and does not interfere with the viewing area while in use. This dramatically cuts the workload and maintenance costs needed for maintaining monitor quality control.

Keep your monitor lit longer with LED backlight
By utilizing an energy-efficient LED as a backlight, the monitor achieves a high-brightness and low power consumption at the same time. Unlike conventional CCFL technology, LED backlighting offers a longer monitor lifespan, is free of hazardous materials, and is therefore compliant with current environmental regulations.

Consistent assurance of image quality
The optional RadiCS software (sold separately) for image quality assurance enables comprehensive maintenance and testing of monitors and covers all areas from calibration through acceptance and constancy testing to archiving. In compliance with AAPM, DIN, IEC and other international standards, RadiCS enables consistent image quality assurance with simple and easy-to-understand procedures.
En savoir plus sur le RX1270
Le polyvalent compact et pratique pour les rapports radiologiques, pour les images couleur et monochromes dans presque toutes les tailles et résolutions.
RadiForce en action
MVZ Radiologie Karlsruhe
En plus du RX1270 pour la mammographie curative, d'autres modèles RadiForce sont utilisés sur différents postes de travail diagnostiques dans le centre de radiologie MVZ de Karlsruhe.
Rest assured with medical qualifications
The monitor meets the strictest medical, safety, and EMC emission standards.

Boîtier
Couleur | Noir |
Equipement | Avec pied |
Dalle
Technologie du panneau | Couleur, IPS |
Rétroéclairage | LED |
Diagonale | 30.9" / 78.4 cm (784 mm diagonal) |
Résolution native | 4200 x 2800 |
Résolution en MP | 12 MP |
Format | 3:2 |
Taille d'affichage active (l x h) | 652.7 x 435.1 mm |
Espacement des pixels | 0.1554 x 0.1554 mm |
Couleurs d'affichage | 10-Bit (DisplayPort): 1.07 milliards (maximum), 8-Bit: 16.77 millions de 68 milliards |
Angle de vision maximal (h/v) | 178° / 178° |
Luminosité maximale | 1200 cd/m² |
Luminosité recommandée par calibration | 500 cd/m² |
Contraste | 1500:1 |
Temps de réponse, rise/fall | 12 ms (noir/blanc/noir) |
Signaux vidéo
Connexion d'entrée | 2x DisplayPort, 1x HDMI |
Fréquence numérique (h/v) | 31-175 kHz, 29-61 Hz |
USB
Ports upstream | 2 ports (USB 2.0 type B) |
Ports downstream | 2 ports (USB 2.0 type A) |
Spécifications électriques
Alimentation | AC 100-240 V, 50/60 Hz |
Consommation d'électricité max. | 188 W |
Consommation d'électricité moyenne | 77 W |
Consommation en mode d'économie d'énergie | < 2 W |
Capteurs
Capteurs | Détecteur du rétro-éclairage, Détecteur intégré de front, Capteur de lumière ambiante |
Équipement et fonctions
Possibilités de réglage | Work-and-Flow (Hide-and-Seek, Switch-and-Go, Point-and-Focus) |
Stabilisation de la luminosité et des couleurs | Oui |
Uniformité de la luminosité et des couleurs (Digital Uniformity Equalizer - DUE) | Oui |
Hybrid Gamma PXL | Oui |
Langues OSD | allemand, anglais, français, italien, espagnol, japonais, suédois, chinois simplifié, chinois traditionnel |
Mode niveau de gris/couleurs préréglés | CAL Switch, DICOM, Custom, CAL1, CAL2, sRGB, Text |
Ergonomie, dimensions et poids
Réglage de la hauteur | 100 mm |
Inclinaison | 30° en arrière, 5° en avant |
Rotation (gauche/droite) | 70° |
Dimensions (avec pied, format paysage, l x h x p) | 689.8 x 508-608 x 225 mm |
Poid avec pied | 15.6 kg |
Poid sans pied | 11.5 kg |
Espacement des trous de montage (Standard VESA) | 100 x 100 mm |
Certificats de contrôle et normes
Marque de contrôle | CE (Medical Device Directive), EN60601-1, ANSI/AAMI ES60601-1, CSA C22.2 Nr. 601-1, IEC60601-1, VCCI-B, FCC-B, ICES-003-B (CAN), RCM, RoHS, China RoHS, WEEE, CCC, EAC |
FDA 510(k) Officialisation | Oui (pour la tomosynthèse mammographie et la radiologie générale) |
Garantie
Garantie | 5 ans |
Contenu de la livraison
Contenu de la livraison | Câble d'alimentation (connecteur CH), Adaptateur secteur / AC adapter, Câble USB, Fixation pour les câbles, Manuel PDF |
Logiciel | RadiCS LE, EIZO ScreenManager Pro Medical |

Medical Graphics Boards
22014 - MED-XN92 Diagnostic Controller